Valve blocks are designed to connect pressure transducers OWEN PD100 and PD200 to the production line by means of impulse tubes, taps or directly in systems of automatic control, regulation and control of technological processes.
Advantages
- Ability to calibrate the sensor in the field
- Factory assembled with leak tests
- Small dimensions and weight
Valve blocks ARIES BV-x
Used in conjunction with pressure transducers. The units consist of a housing, a shut-off valve that isolates the transmitter from the process, and drain valves that drain the media and facilitate field replacement of the transmitter. Also, three- and five-valve blocks allow you to equalize the pressure in the converter chambers to calibrate the zero value of the output signal.
Specifications
Working environment | liquid, steam, gas |
Medium pressure | up to 40 MPa |
Operating environment temperature | -40…+350 °C |
Ambient temperature limits during operation | -40…+85 °С |
Process line connection | M20×1.5 gauge form |
Connecting to the converter | threaded connection M20x1.5 or flange mounting on the transducer with a center distance of 54 mm |
Housing material | AISI 304S stainless steel |
Valve type | graphite sealed needle valve |