Description

With ECG, SpO2, NIBP, Respiration and Temperature measurements as standard, the BM3 monitor meets all your essential requirements. Its unique color display allows you to quickly and efficiently assess all vital parameters. Regardless of the way of application (as bedside or portable), the BM3 monitor is adapted to versatile and flexible applications: network connection to a centralized monitoring station, transport option with connection to the on-board DC network, remote alarm.

Functional, compact and ergonomic , the BM3 monitor gives you the following features:

  • up to 3 curves on a high resolution monitor screen
  • Standard battery operation
  • Arrhythmia analysis
  • Ergonomic design, portability and comfortable bed handle
  • Intuitive menu with convenient control keys
  • The best price / performance ratio

 

SPECIFICATIONS
EKG

  • 3 or 5 leads (optional), user selectable
  • Heart rate range: 30 to 300 bpm
  • Heart rate measurement accuracy: ±3 bpm
  • Bandwidth: 0.5 to 40 Hz
  • Display sweep speed: 25 mm/s
  • ECG size (sensitivity): 0.5, 1, 2, 4 mV/cm
  • Detection of a disconnected lead with its indication on the monitor screen
  • Pacemaker: Detect waveform change and display it on the monitor screen, user selectable
  • Differential input impedance: > 5 MΩ
  • Common mode rejection ratio: > 90 dB at 50 or 60 Hz
  • Input dynamic range:
    – ± 5 mV (= U)
    – ± 300 mV (~ U)
  • Defibrillator shock: < 5 sec
  • Defibrillation artifact recovery time: < 8 sec
  • Arrhythmia Analysis:
    – VTAC/VFIB
    – VTAC
    – ASYSTOLICSpO2
  • Saturation range: 40 to 100%
  • Pulse rate range: 30 to 300 bpm
  • Measurement accuracy:
    – 70 to 100%: ± 2 digits
    – 0 to 69%: undefined
  • Pulse rate accuracy: ± 3 bpmBreath
  • Range: 5 to 120 breaths/min
  • Measurement accuracy: ± 3 breaths / min
  • Display sweep speed: 25 mm/s NIBP
    (Non-Invasive Pressure Measurement)
  • Measurement method: oscillatory
  • Measuring modes:
    – Manual: single measurement
    – Automatic: automatic intervals at 1, 2, 3, 4, 5, 10,15,20,30 min and 1, 2, 4, 8 hours
    – STAT: periodic measurements every 5 minutes
  • Cuff pressure indication:
    30 to 300 mmHg
  • Adjusting the maximum cuff inflation pressure
  • Pressure measurement range:
    – Systolic:
    60 to 250 mmHg
    – Mean arterial pressure:
    45 to 235 mmHg
    – Diastolic: 40 to 220 mmHg
  • Pulse rate range:
    – 40 to 200 bpm
  • Pressure Measurement Accuracy:
    ANSI/AAMI SP10-1992
    Temperature
  • Range: from 15° to 45°C
  • Measurement accuracy:
    – 25° to 45°C: ± 0.2°C
    – 15° to 24°C: ± 0.3°C
  • Compatible with YSI Series 400 Temperature Probes
    GENERAL PARAMETERS
    Display Screen
  • 5.7″ LCD screen
  • High resolution color monitor
    Indicators
  • Up to 3 waveforms (ECG, SpO2, Respiration)
  • Categorized alarm indication system (3 priority levels)
  • Visual alarm
  • Sound signal heart rate
  • Battery status
  • Power on LED indicator
    Interfaces
  • Input connector:
    10 to 16 Volts (= U), 3 A max
  • Defibrillator sync output:
    – Signal level: 0 to 5 V/pulse
    – Pulse width: 100 ± 10 ms
  • Delay from peak of R-wave to start of pulse: 35 ms (maximum)
  • Shunt current: 15 mA
  • Minimum required R-wave amplitude: 0.5 Volts
  • LAN (RS 232) – digital output for data transfer to a computer
  • Nurse call
    Thermal printer (Optional)
  • Up to 3 channels
  • Speeds: 25.50mm/s
  • Paper width: 58mm
    Digital measurements
  • Memory: for 24 hours of work
  • Data saving interval: 1 min
  • Periodicity of data output to the display: 1, 5, 15, 30 min and 1 hour
  • Format of digital measurements:
    – 1 table for all parameters
    – 6 fields per line (time and 5 vital parameters)
Graphic measurements

  • Display interval:
    – during pressure measurement (NIBP)
    – 15 min if no pressure measurement (NIBP)
    – during alarm
  • Periodicity of data output to the display: 30, 60, 90 min, 3, 6, 12 hours
  • Vertically adjustable scale of curves displayed during graphical measurements
    Power supply
  • from 10 to 18 Volts (= U)
  • 2.5 A max
    Battery (standard supply)
  • Internal battery
  • Battery status indicator
  • Operating time: about 2.5 hours (when the battery is fully charged)
  • Operating temperature: 0° to 50°C
  • Food temperature: from – 20° to 60°C
  • Humidity: 5 to 95% (non-condensing)
    Dimensions / Weight
  • Size: H x W x D
    250x238x163 m
  • Weight: 3.5 kg
    Standard accessories
  • 3-Lead Patient Cable
  • Disposable electrodes (10)
  • 3 meter hose for connecting the blood pressure cuff to the monitor
  • Cuff for adults (25 – 35 cm)
  • 2 meter cable to connect the SpO2 sensor to the monitor
  • Reusable SpO2 sensor
  • Mains adapter (18 Volt(= U), 2.5 A)
    Accessories
  • 5-Lead Patient Cable
  • Reusable Body Temperature Measurement Sensor
  • Built-in thermal printer
  • Paper for thermal printer
  • Roll paper support device for bedside use
    Rules and Safety
  • CE 0123
  • Class I, Type CF
  • IEC/EN 60601-1/60601-1-2