Description

A complete set of equipment for high-precision pH measurements and other potentiometric measurements.

Included:

  • measuring transducer
  • ion-selective electrode (ESK 10601 primary verification)
  • thermo sensor
  • tripod
  • magnetic stirrer without heating
  • pH standard titers
  • power unit
  • PC cable
  • software
  • manual

No. 21068 in the State Register of SI RF.
Certificate of conformity (code TN VED_9027801100).
Registers of State Inspection of Ukraine, Kazakhstan, Belarus.

pH meters-ionomers “Expert-001” is a model range of pH meters based on liquid analyzers “Expert-001”. Possibility of expansion for new tasks due to additional configuration with ion-selective electrodes.

Appointment in the basic configuration: measurement of pH, mV, T °C.

pH measurement error complete with pH electrode:

  • 0.03 pH – for the model pH-meter-(ionomer) “Expert-001-1(0.1)”
  • 0.05рН – for models of pH meters-(ionomers) “Expert-001-3(0.1)” and “Expert-001-3(0.4)”

When equipped with ion-selective electrodes, electrodes Eh – measurement of activity, mass and molar concentration of ions, redox potential.

Objects of analysis:

  • sewage, drinking, natural waters.
  • aqueous solutions of samples of plant, food products, soils, etc.

Distinctive features of pH meters-(ionomers) “Expert-001”:

  • compatible with any pH electrode (BNC or K80.7 connector)
  • possibility of independent input of isopotential point
  • automatic and manual compensation for pH measurement
  • number of calibration points for buffer solutions – from 2 to 5
  • calibration according to any pH buffer solutions
  • automatic calculation of measurement results in mV, pX, M, mg/l
  • compatibility with any ion-selective electrodes (optional)
  • storage of calibrations for 32 ions in memory
  • constants for 32 ions in the device memory
  • information output to a portable thermal printer (receipt tape, thermal label)
  • PC connection (software included)
  • powerful battery for battery life
  • bright backlit display
  • power supply of the magnetic stirrer from the device in the field
  • traffic shock resistance
  • low noise level during operation
  • use as a high-resistance millivoltmeter for potentiometric measurements: measurements by the method of standard additions, titration, COD measurements, etc. according to the corresponding MVI.
  • warranty – 24 months

Measurements by:

GOST 26212-91
GOST 26483-85
GOST 26423-85
GOST 17.5.4.01-84
GOST 27979-88
GOST 27753.3-88
GOST 24596.5-81
GOST 29207-91
GOST 26180-84
GOST 24024.5-80
GOST 26781-878
GOST R 514 99
GOST 28972-91
GOST 30648.5-99
GOST 26188-84
GOST 25699.6-90
GOST 938.8-69
GOST 27403-87
GOST 21119.3-91
GOST 12523-77
GOST R 50029-92
GOST 29188.2-91
GOST 23268.9-78
.
GOST 26951-86
GOST 27752.12-88
GOST 27753.0-88
GOST 29270-95
GOST 27753.7-88
GOST 27753.11-88
GOST 50465-93
RD 52.24.394-95
GOST 26425-85
GOST 4386-89
GOST R 51444-99 (ISO 1841-2-96)
GOST 7983-99
GOST 23268.9-78
MUK 4.4.1.008-93
RD 52.24.360- 95
PNDF 14.2:4.87-96
Guidelines TsINAO, M 1990
GOST 23268.5-78
GOST 27753.6-88
PNDF 16.2.2:2.3:3.33-02
PND F 14.1:2:3:4.121-97 (ed. 2004)
PNDF 14.2:4.85-96
PNDF 14.2:4.86-96
ASTM D 512-89
MUK 4.4.1.010-93
RD 52.24.367-95
MU N 5048-89 (approved by the USSR Ministry of Health, 1989)
VNIMI-02-98 RD 52.24 .361-95
MVI 001-101-00 (SE “VNIIFTRI” dated 13.09.00), etc.