Description

Designed for drying seed, food and fodder grains of spiked, leguminous, oilseeds (including rapeseed and sunflower) and other crops of any degree of moisture, as well as for pre-sowing heating of seeds.
They are most effectively used with small-sized combustion plants of the MTU series. Other combustion units of the corresponding power can also be used.

They are built according to various schemes into existing grain drying complexes.
Column diamond-shaped dryers of the SZ series do not require capital foundations and can be installed on foundation blocks, concrete slabs and floors. They do not require special premises, they only need a canopy.
Grain dryers of the SZK series do not require additional protection against atmospheric precipitation.

The dryers have passed state tests at the MIS, there is a certificate of conformity from the certification body ANO Academmash (Moscow), permission from the Federal Service for Environmental, Technological and Nuclear Supervision (Rostekhnadzor) No. РРС 00-36773 for the use of equipment at fire and explosion hazardous production facilities for storage, processing and use of plant materials.

Specifications

SZ-6 SZ-10 SZ-16 SZ-16/20* SZK-30 SZK-40
Productivity for 1 hour of main work, t/h:

– wheat, oats, barley will remove moisture from 19% to 15% (according to foreign methods)

8 13 21 27 40 54

– wheat, oats, barley will remove moisture from 20% to 14% (according to GOST 5886-84)

6 10 16 20 30 40

– rye will remove moisture from 20% to 14%

6,5 11 18 22 33 44

– sunflower will remove moisture from 19% to 9%

3 5 8 10 15 20

Capacity control limits, t/h

4…10 5…18 5…25 5…30 10…50 10…65
Specific fuel consumption for grain drying (with MTU heat generators):

– per square ton (wheat, moisture removal from 20% to 14%), kg

no more than 6 no more than 6 no more than 6 no more than 6 no more than 6 no more than 6

– t/%, kg

no more than 1 no more than 1 no more than 1 no more than 1 no more than 1 no more than 1

Installed power (without heat generator and bucket elevator), kW

40,5 59,0 77,5 85,0 91,0 115,0

Dryer capacity, m3

9,0 14,0 18,0 18,0 40,0 60,0

Dimensions (without heat generator and bucket elevator), LxWxH, m

9.1×1.8×4.7 9.6×3.3×6.5 10.5×3.7×8.5 10.5×3.7×8.5 8.0×7.2×14.5 8.5×7.2×14.5

Weight (without heat generator and bucket elevator), t

3,5 6,5 8,5 8,5 13,0 20,7

* Modification SZ-16 (without grain cooling, with the transfer of the cooling chamber to the drying chamber).