Description
Purpose of the biological safety cabinet class I (code 112. 150 ex. 110.150):
Boxing of biological safety of the I class of protection
- designed to protect the operator and the environment from the release of dispersed contaminated particles when working with dangerous and potentially dangerous pathogenic agents and microorganisms;
- containment of equipment and/or procedures that may generate aerosols;
- does not protect the product in the working chamber from external contamination.
Application of biological safety cabinet class I:
Working with pathogenic agents that are dangerous or potentially dangerous to human health.
Registration certificate of Roszdravnadzor No. FSR 2010/07112 dated 18.03.2010
Standard version of the biological safety cabinet class I (code 112. 150 ex. 110.150):
Working chamber
front glass – hinged, material – tempered glass, the mechanism for opening, closing and holding the glass in the open position is equipped with gas shock absorbers;
- a damper for prevention of blow when closing front glass;
Tempered side windows
Inclined front surface of the box;
lighting of the working chamber;
One block of sockets in the working chamber of the box;
- Stainless steel worktop.
UV block
installed on the rear wall of the working chamber of the box.
Exhaust air purification system
- the cleaning of the air removed from the working chamber occurs through successively installed filters – G4 pre-filter and HEPA – H14 filter.
Elements for connection to the exhaust system
- Removable exhaust hood for connecting the box to the active exhaust ventilation system, the hood is equipped with a compensation gap to exclude the influence of the exhaust ventilation system on the operation of the box.
Elements of the control system
- electroautomatic system – microprocessor;
boxing control panel – push-button with LCD display;
air flow parameters sensors
individual fuse for the power supply line of the main functions of the box (fans, lighting, UV irradiation);
individual fuse for the socket block installed in the working chamber;
The power cable is non-removable.
Stand
stand – frame with a shelf for legs;
transport wheels are provided for moving the box on the stand;
- For stationary installation of the box at the place of operation, screw supports are provided.
Main characteristics of biological safety cabinet BAV-“Laminar-S”-1.5
Boxing class according to GOST R EN 12469-2010, NSF/ANSI 49 | I |
Number of stages of air filtration removed from the working chamber | 2 |
Class of the installed HEPA filter according to GOST R EN 1822-1-2010 | H14 |
Pre-filter class according to GOST R EN 779-2014 | G4 |
The average speed of the air flow entering through the working opening, m/s | 0.7 |
Illumination of the working area (integral value determined over the entire area of the working area), Lx, not less than | 1000 |
Basic parameters and dimensions of the biological safety cabinet dimensions BAV-“Laminar-S”-1.5
Product number | 1R-G.001-15.0 |
Overall dimensions of the box with a stand and with an umbrella, mm (WxDxH) | 1500x760x2080 |
Dimensions of the working chamber of the box, mm (WxDxH) | 1430x625x650 |
Power consumed by the box (without taking into account the load on the socket blocks), W, not more than | 410 |
Total maximum allowable load on socket blocks, W, not more than | 1000 |