Description

Purpose of the biological safety cabinet class I (code 112.120 ex. 110.120):

Class I biosafety cabinet

  • designed to protect the operator and the environment from the release of dispersed contaminated particles when working with dangerous and potentially dangerous pathogenic agents and microorganisms;
  • containment of equipment and/or procedures that may generate aerosols;
  • does not protect the product in the working chamber from external contamination.

Application of biological safety cabinet class I:

Working with pathogenic agents that are dangerous or potentially dangerous to human health.
Isolation of equipment and/or procedures that may generate aerosols.

Registration certificate of Roszdravnadzor No. FSR 2010/07112 dated March 18, 2010

Standard version of the biological safety cabinet class I (code 112.120 ex. 110.120):

Working chamber

front glass – hinged, material – tempered glass, the mechanism for opening, closing and holding the glass in the open position is equipped with gas shock absorbers;

damper to prevent shock when closing the front glass

Tempered side windows

Inclined front surface of the box;

lighting of the working chamber;

One block of sockets in the working chamber of the box;

  • Stainless steel worktop.

UV block :

  • installed on the back wall of the working chamber of the box from above.

Exhaust air cleaning system :

  • the cleaning of the air removed from the working chamber occurs through successively installed filters – G4 pre-filter and HEPA – H14 filter.

Elements for connection to the exhaust system :

Removable exhaust hood for connecting the box to an active exhaust ventilation system, the hood is equipped with a compensation gap to exclude the influence of the exhaust ventilation system on the operation of the box

Elements of the control system :

  • electroautomatic system – microprocessor;

boxing control panel – push-button with LCD display;

air flow parameters sensors;

individual fuse for the power supply line of the main functions of the box (fans, lighting, UV irradiation);

individual fuse for the socket block installed in the working chamber;

The power cable is non-removable.

Main characteristics of biological safety cabinet BAV-“Laminar-S”-1,2

Boxing class according to GOST R EN 12469-2010, NSF/ANSI 49 I
Number of stages of air filtration removed from the working chamber 2
Class of the installed HEPA filter according to GOST R EN 1822-1-2010 H14
Pre-filter class according to GOST R EN 779-2014 G4
The average speed of the air flow entering through the working opening, m/s, not less than 0.7
Illumination of the working field (integral value determined over the entire area of ​​the working area), Lx, not less than 1000

Basic parameters and dimensions of the biological safety cabinet dimensions BAV-“Laminar-S”-1,2

Product number 1R-G.001-12.0
Overall dimensions of the box on supports with an umbrella, mm (WxDxH) 1200x710x1345
Dimensions of the working chamber, mm (WxDxH) 1130x625x650
Power consumed by the box (without taking into account the load on the socket blocks), W, not more than 410
Total maximum allowable load on the built-in socket blocks, W, no more 1000